LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Failed Light
Approved by Historical Upload

Work Order Details

Asset ID
HV2603239
Site
MTN1
Vendor
COX
Circuit
RED (Brake)
Date Actioned
2026-03-12T00:00:00
Week
11
amz-id
amz-2c3kgbpq6z5pyu
Relay Garage

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

RO#873911710 Labor Line 1: COMPLAINT: RED CIRCUIT ISSUE( BRAKE LIGHT) CAUSE: THIRD BRAKE LIGHT INOP CORRECTION: CONNECTED 7 WAY CORD AND CONFIRMED 3RD BRAKE LIGHT WAS INOP, OPENED THE PHILLIPS CONNECT BOX AND VERIFIED THAT POWER WIS PRESENT ACROSS THE BRAKE LIGHT CIRCUIT, POWER IS POWER PRESENT, REMOVED THE LIGHT AND FOUND WIRES CUT, CHECKED FOR POWER AT THE HARNESS POWER IS PRESENT Labor Line 2: COMPLAINT: 3RD BRAKE INOP CAUSE: CUT WIRES CORRECTION: REMOVED AND REPLACED THE LIGHT AND VERIFIED THE LIGHT IS OPERATING CORRECTLY

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:20.878578