LCM Alert Validation

Phase 2 Pilot
Inconclusive
100%
Confidence
Failure Category
No Fault Found
Subcategory
No Fault Found
Approved by Historical Upload

Work Order Details

Asset ID
V570325
Site
PDX9
Vendor
COX
Circuit
RED (Brake)
Date Actioned
2026-03-02T00:00:00
Week
10
amz-id
amz-34z4qkvrd4nz2r
Relay Garage

AI Summary

Technician completed a lot, just not what was asked. Appears to be a failed Grote light based on images from previous WO

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

RO#648510392 Labor Line 1: COMPLAINT: RED CIRCUIT ALERT DETECTED ON PHILLIPS SMART7 CONTROL BOX CAUSE: UNKNOWN/FAULT DETECTED WITHIN TRAILER SYSTEMS CORRECTION: DIAGNOSTIC FOR SMART 7, USING PHILLIPS TECH ASSISTANT SOFTWARE. FOUND FAULT WITH ATIS LAMP SENSOR. ATIS DIAG NEEDED FOR REPAIR. Labor Line 2: COMPLAINT: ATIS LAMP SENSOR FAULT DETECTED WITHIN PHILLIPS SMART SEVEN CONTROL BOX CAUSE: UNKNOWN/ATIS FAULT ON EITHER ELECTRIC ELECTRICAL OR AIR SIDE OF SYSTEM CORRECTION: DIAGNOSTIC FOR ATIS SYSTEM, AND REPAIR AS NEEDED. FOUND MULTIPLE ISSUES WITHIN ATIS SYSTEM. FOUND CORRODED WIRING TO AIR OVER ELECTRIC SWITCH WITHIN ATIS CONTROL BOX. FOUND WIRING WITHIN THE SMART SEVEN JUNCTION BOX WITH EXPOSED WIRING. Labor Line 3: COMPLAINT: REMOVE AND REPLACE ATIS CONTROL BOX CAUSE: FAULTY AIR OVER ELECTRIC SWITCH WITHIN FILTER AND REGULATOR ASSEMBLY. CORRECTION: REMOVE AND REPLACE ATIS CONTROL BOX. Labor Line 4: COMPLAINT: REMOVE AND REPLACE SEVEN WAY RECEPTACLE CAUSE: SEVEN WAY HOUSING CRACKED ON SIDE OF THE TOP NOTCH CORRECTION: REMOVE AND REPLACE SEVEN WAY RECEPTACLE FROM SMART SEVEN. Labor Line 5: COMPLAINT: REPAIR WIRING AND SMART SEVEN CONTROL BOX FOR ATIS CIRCUIT TO LAMP INDICATOR CAUSE: INSULATION ON WIRING TORN, EXPOSING COPPER WIRING. CORRECTION: CUT OUT BAD WIRING, AND STRIP BACK INSULATION TO INSTALL HEAT SHRINK BUT CONNECTORS. Labor Line 6: COMPLAINT: REPAIR CORRODED WIRING IN ATIS CONTROL BOX FOR AIR OVER ELECTRIC SWITCH. CAUSE: WIRING, HEAVILY, CORRODED, SPADE CONNECTORS DISCONNECTED/FELL OFF CORRECTION: CUT OUT CORRODED SECTION OF WIRE, STRIP BACK INSULATION, AND CRIMP ON NEW SPADE CONNECTOR FOR PRESSURE SWITCH CONNECTIONS. RO#648510392 Labor Line 7: COMPLAINT: ADJUST TIRE INFLATION SYSTEM/PSI CONTROL. ONCE NEW ATIS BOX IS INSTALLED. CAUSE: ATIS CONTROL BOX REPLACED WITH NEW, REQUIRING SET UP. CORRECTION: ONCE ATIS BOX INSTALLED, ADJUSTED REGULATOR TO 100 PSI WITHIN CONTROL BOX TO GO TO ALL TIRES, USING A SEPARATE REGULATOR FOR VERIFICATION OF PRESSURE DELIVERED. Labor Line 8: COMPLAINT: TEST ALL LIGHTING AND CIRCUITS AFTER REPAIRS ARE COMPLETE CAUSE: WIRING REPAIRS MADE INSIDE OF SMART SEVEN JUNCTION BOX, AS WELL AS WITHIN ATIS CONTROL BOX CORRECTION: TEST, ALL LIGHTING AND CIRCUITS AFTER REPAIRS ARE COMPLETED. ABS LIGHT ON DUE TO TROUBLESHOOTING AND DIAGNOSTIC. DISCONNECTED, AUXILIARY WIRING, TRAILER NEEDS TO ROLL TO CLEAR ACTIVE FAULTS. Labor Line 9: COMPLAINT: DRAIN ERROR FROM AIR RESERVOIR BEFORE REPLACING ATIS CONTROL BOX. CAUSE: AIR NEEDS TO BE DRAINED IN ORDER TO SAFELY REMOVE AIRLINES AND REPLACE ATIS CONTROL BOX. CORRECTION: DRAIN AIR RESERVOIR, AND ALL AIR FROM TRAILER SYSTEMS TO SAFELY REPAIR ATIS SYSTEM.

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:19.429482

← Back to Deep Dive