LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Failed Light
Approved by Historical Upload

Work Order Details

Asset ID
V508277
Site
IGQ1
Vendor
TA
Circuit
GREEN (Right Turn)
Date Actioned
2026-02-17T00:00:00
Week
8
amz-id
amz-6yr4n275mrt8ny
Relay Garage

AI Summary

PROCESS FOLLOWED AS INTENDED

LCM Current Readings — All Circuits

RED (Brake)
GREEN (Right Turn) ALERTING
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

ESTIMATE COMPLETE TA COMPLAINT PORTION OF LIGHT INOP CORRECTION PERFORMED LIGHT CHECK AND FOUND PS TURN SIGNAL WITH BLOWN LED BULBS I REMOVED LIGHT AND INSTALLED NEW LIGHT PERFORMED LIGHT CHECK AND FOUND ALL LIGHTS WORKING AND VERIFIED ON PCT TECH ASSIST APP THANK YOU MA

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:17.547448