LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Failed Light
Approved by Historical Upload

Work Order Details

Asset ID
GV2202677
Site
MTN1
Vendor
COX
Circuit
GREEN (Right Turn)
Date Actioned
2026-04-01T00:00:00
Week
14
amz-id
amz-anmcbq2sq2rhgm
Relay Garage

LCM Current Readings — All Circuits

RED (Brake)
GREEN (Right Turn) ALERTING
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

RO#356413948 Labor Line 1: Year: 2023, Make: GREA, Model: TRAILER, VIN: 1GR1A0621PK436130, UnitNumber: GV2202677 COMPLAINT: GREEN CIRCUIT ALERT CAUSE: WORN OUT CORRECTION: REMOVED AND REPLACED MID TURN SIGNAL. Labor Line 2: COMPLAINT: GREEN CIRCUIT ALERT CAUSE: DIAGNOSTIC CORRECTION: CHECKED GREEN CIRCUIT FOR ISSUES. FOUND MID TURN SIGNAL WITH ONE LED OUT.

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:22.866729