LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Missing Light
Approved by Historical Upload

Work Order Details

Asset ID
HV2300154
Site
DCA1
Vendor
TA
Circuit
RED (Brake)
Date Actioned
2026-03-13T00:00:00
Week
11
amz-id
amz-bvm9een59ur29w
Relay Garage

AI Summary

Grote light is missing. Technician reported dry run and was unable to identify missing light

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

AUTH AEM TA AEM COMPLAINT CHECK PHILLUPS CONNECT BOX CORRECTION CHECKED PHILLIPS CONNECT AND MADE SURE ALL LIGHTS WORK ALL REQUESTED WORK COMPLETE AEM THE UNIT DID NOT CYLCE ABS WHEN USING THE PHILLIPS APP RAN TEST AND FOUNF IT HAS NO ISSUES IT DID NOT CYCLE AS THE BATT WAS LOW BUT AFTER CAHRGING U P WORKS AS SHOULD THANSK AEM REUQESTED WORK COMPLET

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:20.916231