LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Failed Light
Approved by Historical Upload

Work Order Details

Asset ID
V504057
Site
MTN1
Vendor
COX
Circuit
RED (Brake)
Date Actioned
2026-03-10T00:00:00
Week
11
amz-id
amz-cmwbbx447vs6bh
Relay Garage

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

RO#873911705 Labor Line 1: COMPLAINT: RED CIRCUIT (BRAKE LIGHT) FAULT CAUSE: TROUBLE SHOOT CORRECTION: PLUGGED IN 7 WAY CORD, AND VERIFIED THE BRAKE LIGHT ISSUE, THE THIRD BRAKE LIGHT IS INOP, Labor Line 2: COMPLAINT: THIRD BRAKE LIGHT INOP CAUSE: FAULTY LIGHT CORRECTION: DRILLED OUT THE RIVETS, REMOVED OLD LIGHT, AND DISCONNECTED IT FROM THE WIRE HARNESS, CHECKED FOR POWER AT THE HARNESS, POWER IS PRESENT, CONNECTED A NEW LIGHT, AND THE LIGHT OPERATED PROPERLY, INSTALLED NEW LIGHT AND SECURED IT TO THE CHASSIS WITH RIVETS,

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:20.575511

← Back to Deep Dive