LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Damaged Light
Approved by Historical Upload

Work Order Details

Asset ID
V508215
Site
DCA1
Vendor
TA
Circuit
RED (Brake)
Date Actioned
2026-02-23T00:00:00
Week
9
amz-id
amz-epyfuf4my2t8zn
Relay Garage

AI Summary

Technician replaced corroded 7 way connection and Grote light

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

TA COMPLAINT PHILLIPS CONNECT APP LIGTHING SYSTEM TES T CAUSE REQUEST FOR PHILLIPS CONNECT APP LIGHTING S YSTEM CHECK AES ADDITIONALLY I ATTEMPTED TO CONNECT WITH UNIT AND THE PHILLIPS CONNECT WAS UNABLE TO PARE WITH UNIT I WAS DIRECTLY IN FRONT OF UNIT AND WAS UNABE TO C ONNECT I WILL CALL TECH SUPPORT FOR ASSISTACNE WI TH APP AES ADDITIOANLLY I FOUD 2 DEFECTS WITH IN THE SYSTEM THE 7WAY PLUG HAS CORROSION ON ONE OF PIN TO THE PLUG I ALSO FOUD THAT THE PULSATING BRAKE LIGHT I N THE REAR OF THE TRAIELR IS DIMM THIS LIGHT IS N OT A RQUIRED DOT LIGTH FOR UNIT AND IS AN ACCESSOR Y LIGHT BUT IS CONECTED TO BRAKE CIRCUIT I WILL N EED TO INSPECT THE PULSATING BRAKE LIGTH TO DETERM INE CAUSE OF DIMMNESS AES ADDITIONALLY I TESTED SYSTEM AND FOUND VOLTAGE TO PULSATING BRAKE LIGHT I USED A LOAD PRO TO TEST CIRCUIT FOR CONSUMPTION OF BOLTAH ANDFOUND THAT 1V WAS BEING CONSUMED I CHECK WIRES AND CONNECTION OF LIGHT FOR ANY CORROSION OR BREAKS AND FOUND NON E I BELIEVE THE LIGHT IS DIMM DUE TO BEING A SHOR T IN THE LIGHT ITSELF I WILL NEED TO SOURCE LIGHT I ALSO FOUND THAT THE BRAK LIGHT ON THE LEFT SIDE REAR HAD MULTIPLE HOLES DRILLED INTO LIGHT DUE TO IMPROPER MOUNTING I WILL REPALCE REAR LEFT SIDE B RAKE LIGTH AND CORRECTLY MOUNT NEW LIGHT AES ADDITIONALLY I REPLACED CORRODID 7WAY AND REAR D AAMGED LEFT SIDE BRAKE LIGHT I WILL NEED O SOURCE PULSATING BRAKE LIGHT AND RETURN TO LOT WHEN PART IS REQUIRED AES ADDITIOANLLY ONCE PULSATING LIGHT IS REPLACED I W ILL RETEST SYSTEM USING PHILLIPS CONNECT APP AES

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:18.306159