LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Failed Light
Approved by Historical Upload

Work Order Details

Asset ID
HV2408298
Site
DCA1
Vendor
TA
Circuit
RED (Brake)
Date Actioned
2026-03-30T00:00:00
Week
14
amz-id
amz-qw8uh3z8sfxmet
Relay Garage

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

AUTH TA COMPLAINT RED CIRCUIT ALERT CAUSE WEAR TEAR CORRECTION UPON INSPECTING THE PC BOX I NOTICED T HAT I WAS GETTING OPEN CIRCUIT READINGS ON MULTIPL E CIRCUITS DIDI A WIGGLE TEST AND FOUND 7 WAY FAU LTY REMOVED AND REPLACED THE 7 WAY TO CONTINUE LI GHT CHECK TESTED THE TOP AND BOTTOM POST FOR ALL CIRCUITS TO VERIFY VOLTAGE WAS ABOVE 12V ON ALL AN D NO SPERATIC DIFFERENCES ALL POSTS GOOD PERFOR MED LIGHT CHECK TO VERIFY ALL LIGHTS ARE WORKING N ORMALLY THEY ARE UNIT IS GOOD TO GO TY TECH SB

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:22.330488