LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Lighting
Subcategory
Lighting - Failed Light
Approved by Historical Upload

Work Order Details

Asset ID
V506402
Site
CMH1
Vendor
TA
Circuit
YELLOW (Left Turn)
Date Actioned
2026-03-10T00:00:00
Week
11
amz-id
amz-s3qh4atcn9689p
Relay Garage

AI Summary

Partially failed midturn

LCM Current Readings — All Circuits

RED (Brake)
GREEN (Right Turn)
YELLOW (Left Turn) ALERTING
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

EST TA CHECKED LIGHTS CIRCUIT AND LIGHTS USING PHILLIPS A PP FOR SUPPORT FOUND NOSE BOX HAS BROKEN BOLT THAT WONT COME OUT CHECKED EACH LIGHT AND EACH CIRCUIT ALL WORKING NO ISSUES AT ALL TOOK REQUIRED PICS O F LIGHTS AND APP UPLOADED PICS CHECKED NOSE BOX WI RING HOOKED UP CORRECTLY ALL NUTS PRESENT AND TIGH T ALL WORKING ALL COMPLETE THANK YOU JDP

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:20.412255

← Back to Deep Dive