LCM Alert Validation

Phase 2 Pilot
Defect Detected
100%
Confidence
Failure Category
Other
Subcategory
Wiring - Other
Approved by Historical Upload

Work Order Details

Asset ID
HV2502817
Site
MTN1
Vendor
COX
Circuit
RED (Brake)
Date Actioned
2026-04-02T00:00:00
Week
14
amz-id
amz-vsyncdg62uqe53
Relay Garage

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

RO#356413972 Labor Line 1: Year: 2024, Make: HYUN, Model: TRAILER, VIN: 3H3V532KXSS074418, UnitNumber: HV2502817 COMPLAINT: RED CIRCUIT ALERT CAUSE: WEAR AND TEAR CORRECTION: RECONNECTED POWER SUPPLY CABLE FOR ABS MODULE BACK IN AND MADE SURE IT WAS IN. PUSHED YELLOW RETAINING TAB IN FOR POWER SUPPLY LINE AND CHECKED THAT IT WAS SECURE Labor Line 2: COMPLAINT: RED CIRCUIT ALERT CAUSE: DIAGNOSTIC CORRECTION: CHECKED AND FOUND ALL LIGHTS ON RED CIRCUIT WORKING. FOUND POWER SUPPLY TO ABS MODULE WAS NOT PLUGGED IN AND NOT CYCLING THE ABS SYSTEM UNDER THE RED CIRCUIT POWER (SECONDARY)

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:23.164915

← Back to Deep Dive