Defect Detected
100%
Confidence
Failure Category
Wiring
Subcategory
Smart7 - Wiring in Smart7
Approved by Historical Upload

Work Order Details

Asset ID
V508257
Site
DCA1
Vendor
TA
Circuit
RED (Brake)
Date Actioned
2026-02-23T00:00:00
Week
9
amz-id
amz-xb3sab9qsy7mhm
Relay Garage

AI Summary

Technician determined that all circuits provided power to black circuit due to power bleed and will replace Smart7

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

AUTH TA COMPLAINT PHILLIPS CONNECT APP LIGHTING SYSTEM CH ECK CAUSE REQUEST FOR PHILLIPS CONNNECT APP LIGHTING SYSTEM CHECK AES ADDITIONALLY I FOUND THAT THE SMART 7 BOX HAS A B ROKEN COBER BOLT I ALSO FOUND THAT WHEN THE RED B RAKE CIRCUIT WAS TESTED THE BRAKE LIGHTS WORKED BU T THE MARKER LIGHTS WERE ALSO ON VERY DIMMLY BEING POWERED BY THE BRAKE CIRCUIT I TESTEED AND FOUND THAT WHEN THE BRAKE CIRCUTI IS POWERED 1V2V IS B EING SUPPLIED TO THE MARKER CIRCUIT WHEN THE VRAKE CIRCUIT IS POWERED AES ADDITIONALLY AFTER RUNNING THE LIGHTING SYSTEM CH ECK I FOUND THAT EACH CIRUCUIT IS SENDING AT LEAST 2 VOLTS TO THE MARKER CIRCUIT BOTTOM POST IN THE SMART 7 BOX I TESTED THE MARKER CIRCUIT AND FOUND THAT POWER WAS NOT BLEEDING TO OTHER CIRCUTS I MA DIAGNOSE CAUSE OF BLEEDING POWER TO THE MARKER CIR CUITS AES ADDITIOANLLY I FOUDN THAT THE MY INSPECTOR 920 SY STEM READ EACH CIRCUIT AS GOOD THOUGHT THE POWER B LEED WAS THERE AES ADDITIOANLLY I REMOVED THE WIRES FROM THE MARKER CIRUIT POSTS AND REPOWERED THE BRAKE CIRCUIT AND O THER CIRCUITS AND FOUND THAT THE MARKER POSTS WERE RECIEVING 9 VOLTS WHEN OTHER CIRCUITS WERE POWERE I CHECKED THE POWER POST AND ALSO FOUDN OF THE S MART 7 AND FOUND IT WAS RECIEVING 12V OF POWER AS DESIGNED THE SMART 7 BOX WILL NEED TO BE REPALCED TO PREVENT BLEEDING OF POWER TO CIRCUTS THAT ARE N OT BEING POWERED AES ADDITIOANLLY SMART BOX WILL NEED TO SOURCED AES ADDITIONALLY ONCE SMART 7 BOX IS REPLACED PHILLIP S CONNECT LIGHTING APP WILL BE USED TO RETEST UNIT AES

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:18.388013

← Back to Deep Dive