LCM Alert Validation

Phase 2 Pilot
No Defect Detected
100%
Confidence
Failure Category
No Fault Found
Subcategory
No Fault Found
Approved by Historical Upload

Work Order Details

Asset ID
V502828
Site
DET3
Vendor
TA
Circuit
RED (Brake)
Date Actioned
2026-03-09T00:00:00
Week
11
amz-id
amz-yrn3k3zrk75bft
Relay Garage

AI Summary

This one saw an unusual current spike that lasted for 15 days, then returned to healthy. We'd like to address this eventually, but we will adjust logic to ignore current spikes that last for less than 30 days until we can determine the cause. This is done in an effort to reduce dry run cost

LCM Current Readings — All Circuits

RED (Brake) ALERTING
GREEN (Right Turn)
YELLOW (Left Turn)
BROWN (Marker)
BLACK (Clearance / License Plate)

Vendor WO Notes

EST TA CAUSE C A LIGHTS CORRECTION ACTIVATED LIGHTS FOUND A LOOSE WIRE I N NOSE BOX TIGHTENED IT DOWN LIGHTS ARE FULLY OP ERATIONAL TY

Defect Photos

No defect photos available

LLM Classification (Editable)

Reviewer Input

Approved by Historical Upload on 2026-04-29T12:52:20.263701

← Back to Deep Dive